Enclosure: Cast aluminum containing less than 6% magnesium, with epoxy polyester coating. NEMA 4X (IP65).
Neoprene O-ring cover seals.
Conduit Openings: ¾" NPT
Ambient Temperature: -4 to 149°F (-20 to 65°C)
Storage Temperature: -22 to 176°F (-30 to 80°C)
Relative Humidity: 0 to 95% (non-condensing)
Weight/Shipping Weight: 10 lb/11 lb (4.5/5.0 kg)
Display: Two-line LCD; first line shows process variable (pH, ORP, conductivity, % concentration, oxygen, ozone,
or chlorine), second line shows process temperature and output current. For pH/chlorine combination,
the second line can be toggled to show pH. Fault and warning messages, when triggered, alternate with temperature
and output readings.
First line: 7 segment LCD, 0.8 in. (20 mm) high.
Second line: 7 segment LCD, 0.3 in. (7mm) high.
Display board can be rotated 90 degrees clockwise or counterclockwise.
During calibration and programming, messages and prompts appear in the second line.
Temperature resolution: 0.1°C
Hazardous Location Approval: For details, see specifications for the measurement of interest.
RFI/EMI: EN-61326
Digital Communications: For details, see specifications for the measurement of interest.
HART —
Power & Load Requirements:
Supply voltage at the transmitter terminals should be at least 12 Vdc. Power supply voltage should cover the voltage
drop on the cable plus the external load resistor required for HART communications (250 Ω minimum). Minimum
power supply voltage is 12 Vdc. Maximum power supply voltage is 42.4 Vdc (30 Vdc for intrinsically safe operation).
The graph shows the supply voltage required to maintain 12 Vdc (upper line) and 30 Vdc (lower line) at the transmitter
terminals when the current is 22 mA.
Analog Output: Two-wire, 4-20 mA output with superimposed HART digital signal. Fully scalable over the operating
range of the sensor.
Output accuracy: ±0.05 mA
FOUNDATION FIELDBUS—
Power & Load Requirements: A power supply voltage of 9-32 Vdc at 22 mA is required.
Fieldbus Intrinsically Safe COncept/FISCO-compliant versions of Model 5081 Foundation Fieldbus transmitter are available.
--- Khách hàng có thể lựa chọn một số sản phẩm thay thế tương đương
>>>> Đồng hồ đo lưu lượng
>>>>>Biến tần
>>>>>> Khởi động mềm
>>>>>>> Cảm biến
Khách hàng có thể tham khảo một số dòng sản phẩm được công ty chúng tôi phân phối rất tốt trên thị trường :
>>>
van điện từ ,van thuỷ lực ,xi lanh ,động cơ ,biến tần ,cảm biến ,bộ lọc khí , Bơm thuỷ lực , van tiết lưu ,kính hiển vi
>>>>  Sản phẩm chiến lược của công ty : FESTO , PARKER ,CKD ,KOGANEI , NORGREN , CAMOZZI ,REXROTH
BURKERT ,